Fiat OM Pimespo marka XE25ac Model Forklift Arıza Kodları ve anlamlarını bu başlık altında bulabilirsiniz.
OM Pimespo X25ac Hata Kodları
Alarm | N. Name | Description | Actions |
---|---|---|---|
1 | CAP.CHARGE | The Vcond does not increase on ignition. Possible causes: · power part · logic · driver · motor | Check the power fuse. Check the integrity of the armoured resistance on the 180 Ohm contactors. Disconnect the battery outlet, discharge any charge on the condensers with a resistance (180 Ohm 5 W between the + and the - of the battery on the control) and check that there is no short circuit between the motor terminals and the battery negative. |
1 | CAP.CHARGE | The Vcond does not increase on ignition. Possible causes: · power part · logic · driver · motor | Check the power fuse. Check the integrity of the armoured resistance on the 180 Ohm contactors. Disconnect the battery outlet, discharge any charge on the condensers with a resistance (180 Ohm 5 W between the + and the - of the battery on the control) and check that there is no short circuit between the motor terminals and the battery negative. |
2 | R VMN LOW | Incorrect voltage on the power outputs of the right motor. Possible causes: · power part · driver circuit · motor | Check that the power connections of the motor are correct. Check that there is no insulation loss in the motor. Check that one of the motor phases is not at the battery negative. |
3 | L VMN LOW * | Incorrect voltage on the power outputs of the left motor. Possible causes: · power part · driver circuit · motor | Check that the power connections of the motor are correct. Check that there is no insulation loss in the motor. Check that one of the motor phases is not at the battery negative. |
4 | R VMN HIGH | Incorrect voltage on the power outputs of the right motor. Possible causes: · power part · driver circuit · motor | Check that the power connections of the motor are correct. Check that there is no insulation loss in the motor. Check that one of the motor phases is not at the battery positive. |
5 | L VMN HIGH * | Incorrect voltage on the power outputs of the left motor. Possible causes: · power part · driver circuit · motor | Check that the power connections of the motor are correct. Check that there is no insulation loss in the motor. Check that one of the motor phases is not at the battery positive. |